B2B Electronic Connection Solution

M8 5-Pin Female Sensor Cable Assembly, B-Coded, IP67 Waterproof

Factory-backed connector sourcing and electric connection support for OEMs, distributors and electronic equipment manufacturers.

Product View
M8 5-Pin Female Sensor Cable Assembly, B-Coded, IP67 Waterproof

OEM Ready

Factory Supply

Fast Quote

OEM & Manufacturing Advantages

Partner with us for factory-direct pricing, custom engineering, and complete compliance ready for global markets.

Custom Engineering Support

Tailored cable assembly & wire harness designs to meet your exact application requirements.

Full Technical Datasheets

Electrical ratings, mechanical drawings, material specs and compliance certifications on request.

Factory Direct Pricing

Competitive OEM & distributor pricing with flexible MOQ for both prototype and volume orders.

UL / CE Compliance Ready

Products engineered and tested to meet North American and European regulatory standards.

Need detailed parameters for this product?

Submit a quote request below -- our engineering team typically responds within one business day with full specifications, samples availability and lead times.

Detailed Product Information

Technical Data & Reference

Structured parameters, material notes, application context and frequently asked questions for engineering and procurement evaluation.

Competitor & Cross-Reference

Alternative Type
Intermateable With
Competitor Part Number
TE Connectivity / Phoenix Contact M8 5-Pos B-Coded Sensor Cables (e.g., Phoenix Contact 1507758 or equivalent)
Mates With
Standard M8 5-Pin B-Coded Male Plugs / Panel Mount Connectors

Intermateable: This part is mechanically and electrically compatible for mating with the listed competitor connector. Mixed use in the same connector system is supported.

Technical Specifications

Number of Pins:
5 Pos
Key Position:
B Code
Left Connector:
M8 Socket (Female)
Right Connector:
Flying Leads / Custom
AWG Gauge:
22 AWG
Connection Type:
Threaded Screw Locking (M8 x 1.0)
Wires & Cables Length:
Customization length
Polarization:
B-Coded (Fieldbus)

Material Composition

Material Value / Description
Housing & Insulation: PA (UL94 V-0)
Contacts: Copper Alloy, Gold-Plated
Shell: Copper Alloy, Nickel-Plated
Sealing: NBR
Shielding: Tinned Copper Braid
Overmolding: PVC or TPU
Wires & Cables Conductor: Stranded Tinned Copper
Wires & Cables Jacket: PVC or TPU (Oil-resistant)

Technical Characteristics

Characteristic Value
Rated Voltage: 30V AC / DC
Rated Current: 3A
Contact Resistance: ≤ 5 mΩ
Insulation Resistance: ≥ 100 MΩ
IP Rating: IP67 (when properly mated)
Mating Cycles: ≥ 100 Cycles
Operating Temp (Static): -25°C to +85°C
Operating Temp (Dynamic): -5°C to +80°C

Application Scenarios

  • Industrial Fieldbus Networks: Transmitting reliable Profibus DP and Interbus communication signals between distributed I/O blocks and control units, utilizing B-coding to prevent incorrect mating in complex automation architectures.

  • Factory Automation & Robotics: Delivering secure power and multi-channel control signals to automated machinery and robotic controllers under high-frequency mechanical vibration.

  • Process Control & Washdown Systems: Providing IP67-rated waterproof connectivity for field sensors and actuators in industrial facilities exposed to moisture, cleaning chemicals, and dust.

  • Material Handling & Conveyor Systems: Offering flexible, oil-resistant routing for sensor and bus-line feedback on automated logistics sorting modules and conveyor belts.

Frequently Asked Questions

Why is B-coding important for these 5-pin M8 cables?
B-coding provides unique mechanical polarization, preventing engineers from accidentally plugging these fieldbus cables into standard A-coded sensor ports, thus ensuring system safety and correct data routing.
Are these M8 5-pin female cable assemblies compliant with European and North American standards?
Yes, our products are manufactured under rigorous ISO quality systems and fully comply with RoHS, REACH, and CE standards. We can also provide UL-recognized raw cables upon request to meet specific regional requirements.
Can I choose between PVC and TPU cable jackets?
Absolutely. PVC is ideal for standard indoor static applications due to its cost-efficiency. If your equipment operates in dynamic drag chains or environments exposed to cutting oils and UV light, we strongly recommend our TPU jackets.
What is your Minimum Order Quantity (MOQ) for custom cable lengths or pinouts?
We support flexible manufacturing for both prototype development and volume production. Standard configurations feature low MOQs, while fully customized lengths or specific wire terminations are evaluated based on your exact engineering specs.
What is the typical lead time for bulk orders?
Standard M8 cable assemblies typically ship within 2 to 3 weeks. Custom overmolding, special wire gauges, or non-standard lengths generally require 3 to 5 weeks. Expedited options are available for urgent projects.

Overview and Application Notes

Overview: Engineered for rugged industrial fieldbus and sensor environments, our M8 5-Pin Female Sensor Cable Assembly provides a highly reliable, space-saving connection solution for Profibus, Interbus, and multi-signal automation devices. Featuring a specialized B-coded configuration to prevent mis-mating with A-coded ports and a secure threaded locking mechanism, this compact cable assembly guarantees stable power and signal transmission under severe vibration. Manufactured with robust IP67-rated sealing and shielded cable options, it effectively resists moisture, dust, and electromagnetic interference (EMI). As a factory-direct manufacturer, we offer comprehensive OEM/ODM services, allowing you to customize cable lengths, 22 AWG wire specifications, and jacket materials (PVC/TPU) to seamlessly integrate into your specific industrial equipment.

Application Notes:

  • Torque Specifications: Apply the recommended tightening torque (typically 0.2 Nm for M8 connectors) to the knurled coupling nut to achieve a complete IP67 seal without damaging the internal O-ring.

  • Dynamic vs. Static Routing: Maintain a minimum bend radius of 10x the cable diameter for continuous-flex dynamic applications (using TPU jackets) and 5x for static installations (PVC jackets) to prevent conductor fatigue.

  • Keying & Polarization Check: Visually verify the B-coded keyway alignment prior to mating. B-coding is specifically engineered for fieldbus applications to prevent cross-connection with standard A-coded sensor ports.

  • Shielding Grounding: In environments with heavy electrical noise, ensure the integrated 360-degree shield is properly grounded at the control cabinet panel to preserve high-frequency fieldbus data integrity.

Related Articles

Related Products

Product Document

Download Product PDF

Use this document for internal review, engineering comparison, and RFQ preparation.

e-m8-cables

Build a Reliable Supply Plan for This Product

We support importers, distributors, and electronics manufacturers with product matching, alternative sourcing, assembly integration, and factory-direct production coordination.

Include These Details in Your RFQ

  • 1 Target quantity, annual forecast, and delivery destination.
  • 2 Drawing, datasheet, sample photo, or current supplier part number.
  • 3 Electrical, mechanical, compliance, testing, and packaging requirements.